    Goodman Evaporator Coil Drain Pan Safety Recall
    READ MORE

    Goodman Evaporator Coil Drain Pan Safety Recall

    As with all instances of recalls, it is best to call a qualified technician. Flow Service Experts are available to assist you in completing the requirements of a recall, so you can feel safe and secure. Please read below for some more detailed information on this recall:


    In cooperation with the U.S. Consumer Product Safety Commission (“CPSC”) and Health Canada, Goodman Manufacturing Company, L.P. (“Goodman”) is voluntarily recalling certain molded plastic evaporator coil drain pans that were sold from approximately January 2019 through November 2021.

    This recall applies only to affected drain pans that are verified to be paired in the field with residential condensing gas furnaces installed in an up-flow/vertical configuration.

    To read the complete Press Release, click here for the CPSC and here for Health Canada.

    Affected drain pans were assembled as new equipment with certain evaporator coil models with serial number prefixes ranging from 1901-2101 and were sold from approximately January 2019 through November 2021.

    Affected drain pans were also sold as service parts from approximately January 2019 through November 2021 and may be within the scope of the recall regardless of coil serial number.


    To determine if you have an affected drain pan, Goodman will need:

    1. The serial number of your evaporator coil.
      (If you received an Owner Notice, the coil serial number we have on file for you may be listed on your Notice.)

    They may also need information about:

    1. Your furnace and
    2. Information about your outdoor system (air conditioner or heat pump)

    When you are ready, visit this page and follow the steps outlined.

    CloseTo Top

  • Furnace
    Techical Safety BC: Gas Furnace Report
    READ MORE

    Techical Safety BC: Gas Furnace Report

    We like to keep an eye on the industry to make sure we are always up to speed on the latest developments. We feel when we're informed, you're informed, and that's important to us.

    We found this particular report from Technical Safety BC to be very interesting. It investigates the failure of gas furnaces with polypropylene lined condensing heat exchangers, and why it's important that the customer is made aware of the problem. Following is an excerpt of the report:


    Technical Safety BC received multiple notifications of carbon monoxide exposures that involved failures in a common product line of residential gas burning furnaces manufactured between 1989 and 2011. Although the manufacturer ceased production of these furnaces in 2011, a large number of existing furnaces remain in operation throughout the province. Exposure to carbon monoxide (CO) can be hazardous to health and quickly life threatening if not detected. Technical Safety BC decided to investigate these incidents together to ensure that common factors were identified and thoroughly examined as part of the investigation process.

    Technical Safety BC’s investigation has found that each of the incidents resulted from furnaces that had a common design feature that contributed to the failures, specifically, polypropylene lined secondary heat exchangers. This component was found to be susceptible to corrosion, which interfered with combustion air flow, producing CO. CO was found in occupied living spaces, having escaped the furnaces due to corrosion holes in the heat exchangers or due to corrosion blockage that allowed CO gases to circulate back into the home in certain venting configurations. It was further determined that built-in automatic safety devices did not reliably detect the conditions produced by the corroded secondary heat exchangers.

    Service and maintenance instructions provided with the furnace did not include processes to support owners or contractors in detecting a corroding secondary heat exchanger in advance of failure. Subsequent service bulletins distributed through authorized dealers included procedures to properly diagnose furnace failures that produced elevated CO levels. Efforts to communicate this important procedure with other contractors or homeowners were not evident.

    Technical Safety BC found that the manufacturer’s repair instructions called for replacement of a failed heat exchanger with a new part of the same design and materials. Failures investigated occurred within 20 - 60% of the service life of the furnace heat exchangers and therefore repaired units remain susceptible to repeated failures. The manufacturer stopped producing these furnaces in 2011 but existing furnaces continue to operate, and some failures were reported to Technical Safety BC.

    These furnaces have the potential to release elevated levels of CO for some time before being identified, and occupants may not be made aware of the potential hazard in their homes.

    Exposure to CO can be hazardous or fatal to humans and animals. Heath effects of CO exposures are identified in acute exposure guidelines published by the National Research Council, Appendix F. Disabling effects can occur with 8-hour exposures to concentrations as low as 27 ppm (parts per million), death can occur with 8-hour exposures as low as 130 ppm and in as little as 10 minutes with concentrations of 1700 ppm. Long term exposure to lower levels of CO can also lead to adverse health outcomes...

    If you are interested in more details, here is the full report: Click here for the full report

    CloseTo Top

Flow is your one-stop shop for expert service. We specialize in providing Calgary residents with the most comfortable spaces possible. Whether plumbing, heating and cooling or HVAC services, our professional technicians are certified and ready to help.

CONTACT US


6323 35 St SE
Calgary, AB T2C 1N1

Flow

Service Experts

P: 403.259.3440

E: This email address is being protected from spambots. You need JavaScript enabled to view it.

Normal Office Hours

Monday - Friday 7:30AM - 5:00PM

Site Map 2026 Flow. All Rights Reserved. | Privacy Policy